Redundant systems – we have the necessary experience
Eneria has successfully implemented projects involving installing generator sets for parallel operation. Our generator sets are capable of redundant operation, depending on the plans and needs of the owner of a Data Center project. Redundant power supply solutions ensure the maximum level of machine protection in a server room if the power grid fails.
We minimize the risk of breakdown and increase safety
Our solutions enable improving the reliability of electric power supply to servers via two independent circuits. Each circuit includes a generator set and two groups of UPS. Each server rack at a data center is equipped with two power distribution units (PDU). Each of them is connected to a different power supply circuit.
Remote monitoring and control of generator sets via a high-speed network enables parallel connection of a group of generator sets equipped with a synchronization panel to a single source of the mains power supply.
REDUNDANCY – options
Power supply redundancy increases the safety of data transmission.
Possibilities that every customer has, depending on the security level they want to achieve for their Data Center, are shown below.
CLASSIFICATION | DEFINITION | REDUNDANCY LEVEL | TIER UPTIME INSTITUTE |
N | INDISPENSABLE LEVEL, MEETS THE MINIMUM REQUIREMENTS FOR CAPACITY | LOW
NO COMMENTS |
|
N+1 | ONE UNIT ABOVE THE NEEDS.
THIS CAN REFER TO THE LEVEL OF A COMPONENT OR OF A SYSTEM (N+2, N+3,… FORMS ARE ALSO POSSIBLE) |
MODERATE
A BREAKDOWN OR DISCONNECTION OF SOME COMPONENTS FOR MAINTENANCE PURPOSES WILL NOT IMPACT THE CRITICAL LOAD VALUE. |
TIER i |
2N | TWO ENTIRELY REDUNDANT COMPONENTS OR SYSTEMS. THIS MARKING IS OFTEN USED TO DESCRIBE AN A/B SYSTEM OR A SYSTEM WITH TWO REDUNDANT POWER SUPPLY CIRCUITS | GOOD
ENABLES SIMULTANEOUS MAINTENANCE OF EQUIPMENT AND PROTECTION AGAINST ANY SINGLE POINT OF THE SYSTEM GETTING OUT OF ORDER. |
TIER iI |
2(N+1) | ENSURES TWO ENTIRELY REDUNDANT CIRCUITS OF WHICH EACH HAS AN INDIVIDUAL REDUNDANCY LEVEL. | BEST
ENSURES A POSSIBILITY TO DO REPAIR AND MAINTENANCE WORK, AND TOLERANCE TO BREAKDOWNS AT THE SAME TIME; A SINGLE BREAKDOWN IN ANY POWER SUPPLY CIRCUIT WILL HAVE NO NEGATIVE IMPACT ON THE CAPABILITY OF CIRCUITS TO TAKE OVER THE LOAD. |
TIER iII, TIER iV |
Logical diagram of the redundant power supply of the server room:
Hover the cursor over the marked area to see the legend.
Power network MMC Master Micogrid Controller - synchronization of the operation of electricity sources. CAT power generators. CAT fuel installations. CAT energy storage. Parallel switchboards. Automatic switching system of AS reserve. UPS SYSTEMS. CAT connect remote monitoring. Data Center object. Power network. MMC Master Micogrid Controller - synchronization of the operation of electricity sources. CAT energy storage. Parallel switchboards. UPS SYSTEMS.